Whole-home duct cleaning
Dryer vent cleaning
Camera inspection
Sanitizing & deodorizingWhole-system duct and dryer vent check with before-and-after photos - you see exactly what came out of your vents
That "$99 whole-house special" is a bait ad - the real number appears once they are in your hallway, or the "clean" is a shop-vac at the register. We photograph the inside of your ducts before and after instead.
Aprilaire Vent Sanitizing: The Las Vegas Owner’s Guide
We stock and install Aprilaire-compatible vent sanitizing components throughout Las Vegas, with most replacements running between $240 and $410 installed depending on your model and how much of the housing needs to be swapped. We keep the common Aprilaire panels, UV lamps, and power supplies on the truck, so most jobs are done in a single visit. Where owners usually discover the failure is subtle: the indicator light on the unit dims or quits, the lamp won’t fire, or a faint plastic smell comes from the duct run after the system cycles. In a city where your HVAC runs nine months of the year, a dead sanitizing module means months of unfiltered recirculation before anyone notices.
Which Aprilaire Models This Applies To
Most of what we service falls into two Aprilaire lines: the inline duct-mounted sanitizing modules (like the older 1900 series and similar whole-house air purifiers with UV) and the standalone vent sanitizers that mount at a single return or supply register. The trick with Aprilaire is that the power supply and the bulb are sold as paired components on some models, but on others they’re separate part numbers, and mixing generations is a common mistake. If you’re pulling the old module out and it has a blue-tinted glass tube with a four-pin connector, that’s the older OEM style. The newer ones use a two-pin connector and a different ballast. Aprilaire changed that pin layout around 2018, which means the bulb from a 2016 unit won’t seat into a 2020 housing even though they look nearly identical at a glance.
We’re an independent service provider, not affiliated with Aprilaire. What that means practically: we stock genuine Aprilaire replacement components and also carry quality aftermarket equivalents where they’re a better value. For bulbs specifically, the aftermarket units we install use the same UV-C wavelength and wattage as the OEM part. For control boards and power supplies, we recommend staying with genuine Aprilaire parts because the aftermarket versions have a higher early-failure rate in our experience. Las Vegas heat ages capacitors and solder joints faster than anywhere we’ve worked, and the OEM boards simply hold up longer.
Styles & brands we work with




Signs Your Aprilaire Vent Sanitizing Is Failing
- Indicator light is out or blinking irregularly. Most Aprilaire modules have an LED or small display that confirms the lamp is receiving power. If it’s dark, blinking in a pattern you’ve never seen, or flickering, the ballast or power supply is usually the culprit, not necessarily the bulb itself.
- Lamp won’t fire after a power cycle. UV lamps don’t fail gradually like incandescent bulbs do. They dim over 9,000 to 12,000 operating hours, then stop firing altogether. If you reset the breaker and the lamp still won’t ignite, it’s past its rated life.
- Faint ozone or burning plastic smell from the duct run. This is the one we tell people not to ignore. A failing ballast can overheat, and in the Las Vegas summer when the system runs nearly continuously, that heat builds fast. Shut the unit off at the breaker and call us.
- Visible bulb darkening or white powder inside the glass tube. UV-C bulbs develop a gray or black tint near the ends as they age, and you may see a fine white residue inside. That’s the mercury vapor deposit breaking down. Time to replace.
- Increased dust accumulation near the supply vent where the sanitizer sits. The UV module isn’t the main filter in the system, but when it’s working properly, it reduces the microbial growth that makes dust clump. A dead module often correlates with dustier vent grates in that room.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
In Las Vegas, expect to pay between $240 and $410 for a complete Aprilaire vent sanitizing replacement installed. The lower end covers a bulb-only swap on a compatible housing. The higher end covers a full module replacement with a new power supply and bulb, or a repair that requires pulling the duct run to access the mounting point. We give you a written price before any work begins, so you know the number before we touch a tool. The price you see is the price you pay.
Here’s how the range typically breaks down in the Las Vegas market:
- UV bulb replacement (OEM Aprilaire): $90 – $160 for the part, plus $100 – $130 for labor and diagnostics.
- Aftermarket UV-C bulb equivalent: $55 – $95 for the part, same labor range.
- Power supply / ballast replacement: $110 – $180 for the part, plus $100 – $150 for labor, depending on access.
- Full module replacement (bulb, ballast, housing, mounting): $260 – $410 installed, parts and labor together.
Every Aprilaire vent sanitizing repair we do is covered by our 365-Day Done Right Promise in writing. If the part fails or the repair doesn’t hold within a year, we come back and make it right at no charge.
DIY or Call Us?
Here’s the honest split. If you’re just checking whether the bulb is dark or the indicator is dead, you can look at that yourself. But opening the housing to swap a UV-C bulb means handling a glass tube that emits ultraviolet light harmful to skin and eyes, and working with a ballast that holds a charge even when the unit is off. That’s the part where DIY goes sideways. We’ve had calls from Las Vegas homeowners in Green Valley and Summerlin who opened a module, touched the wrong contact, and got a shock or a face full of glass dust. It’s not worth it.
If you want to check compatibility before calling, grab the model number off the Aprilaire label inside the housing or on the power supply. Take a photo. Text it to us when you call, and we’ll tell you over the phone whether we have the part on the truck before we ever schedule a visit. Our phone line is answered by a live person, day or night, at (725) 726-5532.
FAQs
Expect 9,000 to 12,000 operating hours, which in a Las Vegas home with the HVAC running 7 to 9 months a year translates to about 2 to 3 years of real-world life, not the 5 years some packaging suggests. High static pressure, frequent cycling, and our dry desert air all shorten lamp life. Call (725) 726-5532 and we’ll check your specific model’s rated hours.
We do repairs on Aprilaire power supplies when the issue is a simple capacitor or solder joint failure, which happens often in Las Vegas heat. If the board has multiple failed components, replacement is cheaper and more reliable. We’ll tell you which path makes sense for your unit and show you the failed part in person before we proceed.
Most Aprilaire bulb or power supply replacements take 45 minutes to 2 hours, start to finish. If we need to pull a section of duct to access the mounting point, it can run 3 to 4 hours. We’ll give you a time window and a written price before work starts, so there are no surprises.
Yes. We carry common Aprilaire bulbs, power supplies, and complete modules on the truck, along with compatible aftermarket bulbs and parts for Lennox, Trane, and Carrier systems. If your specific model needs something we don’t have on board, we can usually have it in hand within one business day.
If your Aprilaire vent sanitizing module is dark, flickering, or smelling like burnt plastic, shut it off and call us at (725) 726-5532. We’ll give you a straight answer on what’s wrong, what it costs to fix, and when we can be there. The name and photo of your technician arrive before the visit, and the price is in writing before any work starts.
Written by Marcus Veale, Owner, Linden Air Duct Las Vegas at Linden Air Duct Las Vegas, serving Las Vegas and nearby areas.